Current location:HOME>PRODUCT>Kinematic viscosity tester>Fully Automatic Kinematic Viscosity Tester for Automated Petroleum Testing
Fully Automatic Kinematic Viscosity Tester for Automated Petroleum Testing

Fully Automatic Kinematic Viscosity Tester for Automated Petroleum Testing HM-YN3-1

【Introduction】Fully automatic kinematic viscosity tester featuring 0.01s time resolution, 1000W heating power, dual-channel simultaneous testing, infrared photoelectric detection, and automatic suction, measurement, cleaning, and drying workflows.

Product details

Kinematic viscosity tester with constant temperature glass bath and capillary measurement ports

Core feature icons of kinematic viscosity tester including touchscreen precision control and MCU architecture

Kinematic viscosity testing application scenarios across chemical pharmaceutical and food processing industries

Application coverage in printing inks textile dyes cosmetics formulation and research laboratory testing

Lineup comparison of benchtop kinematic viscosity testers including HM-YN1 HM-YN2 and HM-WYN models

Automated and portable kinematic viscosity tester models including HM-YN3-1 HM-YN3-2 and HM-YN4

High-precision temperature control system with German A-grade Pt100 stainless steel sensor probe

Dual viscosity measurement methods supporting both Pinkevitch and Ubbelohde capillary viscometer types

Intelligent touchscreen user interface displaying sample testing settings history and system configuration

Fully automatic kinematic viscometer with fiber-optic infrared detection and automated cleaning system

Low-temperature automatic kinematic viscosity tester featuring built-in compressor refrigeration unit

Portable automatic kinematic viscometer in three-proof protective carrying case for field testing

Compliance with kinematic viscosity testing standards including GB/T265 GB/T1841 and SY/T5651

Technical specifications comparison table for HM-YN1 HM-YN2 and HM-WYN kinematic viscosity testers

Technical specifications comparison table for HM-YN3-1 and HM-YN3-2 fully automatic viscosity testers

Technical specifications table for HM-YN4 portable automatic kinematic viscometer

Shandong Hengmei Electronic Technology corporate headquarters team and instrument manufacturing facility

Laboratory research analysts performing analytical sample testing and instrument calibration workflows

Product Overview

In commercial third-party inspection centers, oil condition monitoring laboratories, and refinery quality control units, processing dozens of daily oil samples using manual capillary viscometers incurs excessive labor costs and introduces operator timing discrepancies. The HM-YN3-1 eliminates subjective timing errors through its automated optical liquid detection and automated post-test solvent rinse and air dry cycle. Operators simply introduce the sample container and initiate the program; the instrument completes the analysis, logs the record, cleans the capillary tube, and prepares for the next test sequence.

Key Features

  • Comprehensive automation workflow: automatic suction, timing, calculation, printing, cleaning, and drying
  • Dual-channel architecture supporting simultaneous testing of two independent fluid samples
  • Extensive measurement span covering 0 to 30,000 mm²/s with fine 0.01 s time resolution
  • Infrared photoelectric liquid detection ensuring repeatable, operator-independent meniscus timing
  • High-precision thermal bath spanning ambient to +150°C with ±0.01°C stability
  • 10-inch industrial color touchscreen with structured test parameter management
  • Internal memory capacity storing up to 10,000 test results with integrated thermal printer
  • Closed-loop capillary solvent cleaning and forced-air drying system minimizing solvent exposure

Applications

The HM-YN3-1 is deployed across high-throughput fluid quality environments:

  • Lube Blending Plants: Automated batch validation of base oils, finished motor oils, and industrial lubricants.
  • Used Oil Analysis: In-service oil degradation monitoring for fleet transport, mining equipment, and turbines.
  • Petrochemical Refineries: Routine quality verification of diesel, light gas oils, and residual blend stocks.
  • Commercial Laboratories: High-volume contract sample processing requiring auditable testing sequences.

Technical Specifications

ParameterSpecification
Instrument ModelHM-YN3-1
Automation LevelFully automatic (suction, measurement, calculation, cleaning, drying)
Test Channels2 channels (simultaneous dual-sample testing)
Measurement Range0 ~ 30,000 mm²/s
Time Resolution0.01s
Temperature RangeAmbient ~ +150°C
Temperature Measurement Accuracy±0.01°C
Temperature SensorGerman A-grade Pt100 stainless steel probe
Heating UnitElectric heating unit, Max 1000W (Max power consumption: 1500W)
Liquid Level DetectionInfrared photoelectric detection
Temperature CalibrationAvailable
Display Screen10-inch industrial color touchscreen
Data Storage Capacity10,000 test results with built-in thermal printer
Operating EnvironmentOperating temperature: 10 ~ 40°C, Storage temperature: 0 ~ 50°C
Power SupplyAC 220V, 50Hz

Configuration and Accessories

  • HM-YN3-1 Fully automatic kinematic viscometer main body
  • Dual-station automatic capillary viscometer assembly
  • Solvent cleaning bottles and waste liquid recovery reservoir
  • Integrated pneumatic suction and drying pump module
  • German A-grade Pt100 sensor and thermal printer
  • Power cable, tubing connections, and operating manual

Related Models

For applications demanding higher timing resolution (≤0.0005s), fiber-optic sensing, and manual exclusion of experimental anomalies, select the HM-YN3-2. For mobile field testing, consider the battery-operated portable HM-YN4. For manual multi-method testing, examine the HM-YN1 or HM-YN2.

Product Enquiries

Contact our sales representative for product enquiries, configuration information and coordination of service requests.

Sales Contact: Arthur
Email: Arthur@hmdzkj.cn
Tel / WhatsApp / WeChat: +86 18353666151


Article address:https://www.petrocheminstrum.com/pro7/hm-yn3-1-automated-petroleum-viscosity-testing.html