Automatic Open-Cup Flash and Fire Point Tester HM-KS2
Product details













Product Overview
The HM-KS2 from HM Instruments is an automatic open-cup flash and fire point tester for suitable petroleum products and other flammable liquids. It follows a controlled heating profile, applies electric ignition near the expected flash point and records flash-point and fire-point results.
Key Features
- A 7-inch Android touchscreen displays real-time temperature curves and supports Chinese/English switching.
- Automatic result capture and built-in thermal printing support routine test records.
- An A-grade three-wire PT100 sensor provides temperature sensing with compensation.
- Instrument self-checks cover the moving mechanism, ignition, printer and cooling fan.
- Data export and eMMC-based storage support management of test records.
Applications
Use in petroleum, railway, aviation, power-generation and research laboratories where a Cleveland open-cup flash or fire point result is required. Select the procedure for the liquid and the specification being applied.
Technical Specifications
| Parameter | Specification |
|---|---|
| Cup method | Cleveland open cup |
| Results | Flash point and fire point |
| Measurement range | Ambient to 400 °C |
| Display | 7-inch Android touchscreen, 1024 × 600 pixels |
| Temperature sensor | A-grade PT100, three-wire with compensation |
| Barometer accuracy | ≤0.5 kPa |
| Specified repeatability | ≤4 °C |
| Ignition | Electric |
| Heating rates | 14–17 °C/min until 56 °C below expected flash point; 5–6 °C/min starting 23 °C below expected flash point |
| Flash detection | Flame ionization |
| Post-test cooling | Automatic fan cooling |
| Record storage | Capacity depends on available eMMC space |
| Printer | Built-in thermal printer |
| Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power | ≤600 W |
| Ambient temperature | 10–35 °C |
| Relative humidity | <85% |
| Dimensions | 430 × 280 × 350 mm (L × W × H) |
| Weight | 11.3 kg |
| Method references | ASTM D92; GB/T 3536-2008; ISO 2592:2000 |
Operation and Selection
The open-cup configuration measures flash point and fire point. Use a closed-cup model when the governing procedure requires a closed-cup flash point. Set the expected flash point and procedure before the run and use the prescribed sample amount with ventilation and fire precautions suitable for heated flammable liquids.
Product Enquiries
Tell our sales representative your sample material, required method and configuration needs for product enquiries and coordination of service requests.
Sales Contact: Arthur
Email: Arthur@hmdzkj.cn
Tel / WhatsApp / WeChat: +86 18353666151
Article address:https://www.petrocheminstrum.com/pro3/hm-ks2-open-cup-flash-fire-tester.html
- Previous: Automatic Closed-Cup Flash Point Tester
- Next: no more